Basic Info.
After-sales Service
Overseas Engineers Supported
Selected Voltage
220V/50HZ
Application Machine
CNC Machine Tools
Item Name
China Low Temperature Air Cooled Chiller Supplier
Refrigerant
R22, R502, R134A, R404A
Cooling Capacity
1.53kw-180kw
Min. Outlet Water Temp.
-120 Degree C (Adjustable)
Power Voltage
220V, 380V (Custom Made)
Transport Package
Plywood Case
Specification
As per technical sheet
Product Description
China Low Temperature Air Cooled Chiller Supplier Product Description
The main four components of air-cooled chiller: Compressor, finned condenser, cut-off valve and evaporator.
Refrigeration principle:
Compression compressor provides circulating pressure for refrigerant (Freon) in the refrigeration system; the compressed refrigerant becomes high temperature and high pressure gas through finned condenser and is cooled by the natural air extracted by the fan to become medium temperature and high pressure gas; the medium temperature and high pressure refrigerant enters the evaporator after passing through the small diameter of the interceptor valve and rapidly expands and vaporizes into gas, and the temperature of the evaporator becomes low and then cools with cooling water. After vaporization, the refrigerant gas is inhaled again by the compressor for compression and circulation. Thus to achieve the purpose of cyclic refrigeration.
Air-cooled chilled features:
1. The unit uses a large brand of fully enclosed scroll compressor, stable operation, long service life.
2. Equipped with multiple protection devices, simple operation, easy maintenance.
3. Air-cooled chiller can use a single or multiple compressor combination, power can be customized according to the load power, function can also be automatically adjusted during operation to maximize energy saving.
4. The outer shell of the machine case adopts electrostatic spraying anti-rust treatment, with beautiful appearance and reasonable structure.
5. according to the actual cooling process can choose whether to install built-in water storage tank and circulating water pump.
Applications: Rubber & plastic industry, automotive parts production and testing, processing machinery, biochemical reactors, electronics industry, food processing storage and other R & D, manufacturing, storage process temperature control.
Our Advantages
1. Compressors of Copeland, Danfoss, Sanyo, Tecon and other brands from USA, Europe and Japan.
2. Refrigerants such as R22, R502, R134A and R404A can be used according to the compressor type and application.
1. Condenser is made of copper tubes and aluminium foil sheets.
2. Coil heat exchanger has a larger heat transfer area than other designs, resulting in uniform surface air velocity and stable in heat transferring.
3. Trapezoidal internal thread structure, 30% more efficient.
1. The evaporator adopts coil type purple copper tube and box type straight purple copper tube.
2. The copper tube has threads on the inner surface, which has good heat exchange effect.
3. Stainless steel water tank adopts 25mm PE insulation board, no condensation and less cold loss.
Product Parameters
Data | Model | DL-1/2AS | DL-01AS | SJ-02AS | SJ-03AS | SJ-04AS | SJ-05AS | SJ-06AS | SJ-08AD |
Cooling capacity | kW | 1.53 | 2.94 | 5.67 | 8.86 | 10.9 | 14.5 | 17.2 | 21.8 |
Kcal/h | 1316 | 2528 | 4872 | 7620 | 9374 | 12470 | 14792 | 18748 |
Input power | kW | 0.68 | 1.31 | 2.6 | 3.45 | 4.22 | 4.97 | 5.47 | 8.6 |
Main power voltage | 1N~220V 50HZ | 3N~380V 50HZ |
Refrigerant | Type | R22 (Options for R502, R134A and R404A) |
Filling volume (KG) | 0.6 | 0.8 | 1.6 | 2 | 2.4 | 3.3 | 3.9 | 2.4*2 |
Control mode | Capillary |
Compressor | Compressor type | Fully enclosed gyratory | Fully enclosed scroll or piston type |
Power (kW) | 0.55 | 0.75 | 1.5 | 3.07 | 3 | 4.22 | 4.68 | 3*2 |
Cooling air volume | m³/h | 800 | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 |
Chilled water | Flow rate (m³/h) | 0.26 | 0.51 | 0.97 | 1.53 | 1.87 | 2.4 | 2.91 | 3.75 |
Water tank (m³) | 0.022 | 0.028 | 0.038 | 0.06 | 0.06 | 0.07 | 0.11 | 0.11 |
Inlet/outlet pipe size | G1/2" | G1/2" | G3/4" | G3/4" | G3/4" | G1 | G1 | G1-1/2" |
Water pump | Motor power (kW) | 0.375 | 0.375 | 0.375 | 0.375 | 0.375 | 0.75 | 0.75 | 0.75 |
Pressure (KPa) | 180 | 180 | 250 | 242 | 242 | 290 | 290 | 290 |
Overall size (L*W*H) | mm | 600 | 600 | 820 | 945 | 945 | 1035 | 1200 | 1470 |
mm | 400 | 400 | 460 | 550 | 550 | 610 | 650 | 710 |
mm | 940 | 940 | 1170 | 1370 | 1370 | 1385 | 1480 | 1700 |
Net weight | kg | 45 | 60 | 100 | 130 | 160 | 190 | 220 | 270 |
Data | Model | DL-10AD | DL-12AD | DL-15AD | DL-20AD | DL-25AD | DL-30AT | DL-40AF | DL-50AF | DL-60AF |
Cooling capacity | kW | 29 | 34.4 | 44.5 | 60 | 76 | 90 | 120 | 152 | 180 |
Kcal/h | 24940 | 29584 | 38270 | 51600 | 65360 | 77400 | 103200 | 130720 | 154800 |
Input power | KW | 11 | 12 | 15.5 | 20 | 22.1 | 31.75 | 39.35 | 48.7 | 60.7 |
Main power voltage | 3N~380V 50HZ/60HZ |
Refrigerant | Type | R22 (Options for R502, R134A and R404A) |
Filling volume (KG) | 6 | 8 | 9 | 12 | 16 | 20 | 25 | 32 | 40 |
Control mode | Capillary | External balance force thermal expansion valve |
Compressor | Type | Fully enclosed scroll or piston type |
Power (kW) | 4.22*2 | 4.68*2 | 8.2+4.22 | 8.1*2 | 9.15*2 | 8.1*3 | 8.1*4 | 9.15*4 | 8.186 |
Cooling air volume | m³/h | 10000 | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 | 48000 | 66000 |
Chilled water | Flow rate (m³/h) | 4.82 | 5.81 | 7.6 | 10.16 | 12.34 | 15 | 19.53 | 23.3 | 30.52 |
Water tank (m³) | 0.188 | 0.188 | 0.285 | 0.285 | 0.405 | 0.405 | 0.61 | 0.61 | 0.7 |
Inlet/outlet pipe size | G2" | G2" | G2" | G2" | G2-1/2" | G2-1/2" | G3" | G3" | G3-1/2" |
Water pump | Motor power (kW) | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | 4 | 4 |
Pressure (KPa) | 205 | 205 | 205 | 220 | 220 | 250 | 250 | 250 | 250 |
Overall size (L*W*H) | mm | 1470 | 1600 | 1680 | 1955 | 2080 | 2400 | 2250 | 2700 | 3400 |
mm | 710 | 800 | 890 | 940 | 1000 | 1100 | 1550 | 1620 | 1800 |
mm | 1435 | 1600 | 1600 | 1600 | 1800 | 1800 | 1820 | 1850 | 1850 |
Note: The nominal refrigeration capacity is based on: inlet water temperature 15°C, outlet water temperature 10°C, ambient temperature 35°C. Company Profile
Certifications
Packaging & Shipping
Why Choose Us
FAQ
DELON has been marketing the industrial chillers for nearly 10 years, and we have encountered all kinds of problems, here are the most important concerns of our customers before closing the deal.
1) Can your chiller meet the cooling needs of my production?
If this is your first purchase, all the specifications and the operation requirements should be provided, our engineers will calculate and advise the suitable models for your reference.
2) What are the payment terms?
For new customers, usually we accept the 35% T/T as the prepayment, the balance shall be paid before shipment, and if you have been with us for years or due to the restrictions of foreign exchange policy, we do offer L/C at sight.
3) Do you provide customized service?
We can design the machine according to your requirements (temperature, material, power, control mode, control accuracy, etc.) We will also provide you with expert guidance at the same time, based on our years of experience in this temperature control field.
4) How long does it usually take to manufacture?
Depends on whether you want to do customization your electric oil heaters or not and also depends on the quantity you want to order.
For regular machines in LCL, the lead time is 5-10 working days.
For customized products and bulk orders in FCL, the lead time is 15-30 working days.
5) What's the warranty for the machine?
Generally, the warranty 24 months counting from the date against shipment, during the warranty period, if there's any parts damaged in quality, you can get the new ones for free.
6) Do you test the machine after the production?
Before shipment, our engineer will arrange the functional tests for each machine.
7) Can I come to China for factory inspection?
Of course, but it is better to wait until the epidemic subsides. Now we support using ZOOM for online factory inspection.
8) How often should the thermal oil be changed?
Depends on frequency of use, generally speaking, you need to change the thermal oil every 6 to 12 months.
9) What's the Refrigerant do you adopt for the chiller?
Normally, we adopt R404A and R507C, if your standard is higher, then we could use the R448A.
Address:
No. 18, Yangzi Road, Yangshe Town, Suzhou, Jiangsu, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Industrial Equipment & Components, Manufacturing & Processing Machinery, Service
Management System Certification:
ISO 9001
Company Introduction:
Zhangjiagang Delon Thermal Machinery Co., Ltd. is a leading independent heavy machinery supplier in China. We′re a high-tech enterprise integrating energy conservation, environmental protection, clean energy product development, thermal engineering, boilers and pressure vessels. The company has strong technical strength and sophisticated production equipment.
Main Products: Commercial & Domestic Water Heaters, Industrial Boilers, Marine Boilers and other related products including Mold Temperature Controllers, Chillers, etc…
Commercial & Domestic Water Heaters have passed "ISO9001: 2000". The products have "China CCC Compulsory Certification", "EU CE Certification", in line with the commercial electric water heater safety standards stipulated by ASME-HLW and CE.
Industrial Boilers fully implement ISO9001: 2000, ASME and EU CE standards.
Marine Boilers fully implement the quality system standards such as GB/T19001 and CCSR9001, and can design and manufacture products that meet the requirements of CCS, DNV, GL, BV, ABS, RS, RINA and other classification society standards and establish a suitable product.
The purpose of DELON is to carefully design, carefully manufacture and meticulously serve each of your investments; To maximize the return on your investments, as an eternal theme.