Basic Info.
Drum Placement
Horizontal Boiler
Burning Style
Chamber Combustion Boiler
Item Name
Horizontal Fire Tube Industrial Steam Boiler Facto
Steam Capacity
0.5t/H-10t/H
Available Fuel
Natural Gas, Light Diesel, Heavy Fuel Oil
Rated Working Pressure
0.7MPa-3.8MPa (Custom Made)
Saturated Steam Temperature
170degree C-247degree C
Thermal Efficiency
88%-93%
Burner Brand
Weishaupt, Oilon, Riello, Baltur, Unigas
Main Power Voltage
380V/50Hz, 3pH (Custom Made)
Transport Package
Plywood Case
Specification
As per technical sheet
Product Description
Horizontal Fire Tube Industrial Steam Boiler Factory
Product Description
1. WNS Series Horizontal Oil (gas) fired steam boiler, adopting international most mutual three pass all wet back structure with horizontal layout. Fully automatic boiler operation, after the atomization of fuel by burner and the waveform furnace is full of fire, and transfers radiant heat by furnace, this is the first pass. There will form cluster of high temperature smoke in combustion chamber then turn into the second pass, that is threaded pipe bundle area. After the convection heat transfer, the smoke temperature is gradually reduced to the former after the smoke box, and in this move into the third return, The tube bundle area, and then after the smoke through the chimney into the atmosphere into the box.
2. Supporting the world famous burners, advanced control panel (main components are imported), valve, pump afopt high-quality brand, reliable boiler accessories to ensure the safe operation and improve the overall quality of the boiler.
3. This series boiler is more human, more secure automatic intelligent control, it has many features, such as high efficiency, energy saving, easy maintenance, durability, etc.
Our Advantages
Product Parameters
Model | WNS0.5-0.8-Y.Q | WNS0.75-0.8-Y.Q | WNS1-1.0-Y.Q | WNS1.5-1.0-Y.Q | WNS2-1.0-Y.Q | WNS3-1.0-Y.Q |
Item | Unit |
Rated steam capacity | t/h | 0.5 | 0.75 | 1 | 1.5 | 2 | 3 |
Rated working pressure | MPa | 0.8 (1.0, 1.25, 1.6) | 1.0 (1.25, 1.6, 2.0, 2.5) |
Saturated steam temperature | ºC | 175 (184, 193, 204) | 184 (193, 204, 213, 224) |
Heating surface (with economizer) | m2 | 14.3 | 19.6 | 25 | 36 | 58.8 | 98.6 |
Fuel Consumption | Light diesel | kg/h | 34 | 51 | 68 | 102 | 136 | 204 |
Heavy fuel oil | Kg/h | 35.36 | 53 | 69.7 | 104 | 139.4 | 210 |
Natural gas | Nm3/h | 37 | 56 | 74 | 111 | 148 | 222 |
LPG | Nm3/h | 13.4 | 19.5 | 26 | 39.1 | 56 | 85 |
Main steam outlet valve diameter | PN | 16 (20, 25) |
DN | 40 | 50 | 50 | 65 | 65 | 80 |
Air vent valve diameter | PN | 16 (20, 25) |
DN | 20 | 20 | 25 | 25 | 25 | 25 |
Safety valve diameter | PN | 16 (20, 25) |
DN | 40 | 40 | 50 | 2×40 | 2×40 | 2×40 |
Water inlet diameter | PN | 16 (20, 25) |
DN | 25 | 25 | 25 | 32 | 40 | 40 |
Blow-down valve diameter | PN | 16 (20, 25) |
DN | 40 | 40 | 40 | 40 | 50 | 50 |
Overall dimension | L | mm | 3550 | 3870 | 4010 | 4530 | 5260 | 5780 |
W | mm | 1900 | 2000 | 2100 | 2380 | 2600 | 3100 |
H | mm | 2800 | 3030 | 3200 | 3500 | 3780 | 3950 |
Max. transportation size of boiler (L1xW2xH2) | mm | 3040x1420 x1900 | 3200x1630 x2000 | 3450x1900 x2040 | 3910x2000 x2260 | 4450x2200 x2450 | 4890x2340 x2520 |
Net Weight | Ton | 3.6 | 4.1 | 4.5 | 6.3 | 8.5 | 11.6 |
Model | WNS4-1.25-Y.Q | WNS5-1.25-Y.Q | WNS6-1.25-Y.Q | WNS8-1.25-Y.Q | WNS10-1.25-Y.Q |
Item | Unit |
Rated steam capacity | t/h | 4 | 5 | 6 | 8 | 10 |
Rated working pressure | MPa | 1.25 (1.6, 2.0, 2.5, 3.8) |
Saturated steam temperature | ºC | 193 (204, 213, 224, 247) |
Heating surface (with economizer) | m2 | 111.8 | 163.1 | 181.17 | 190.77 | 232.16 |
Fuel Consumption | Light diesel | kg/h | 272 | 340 | 408 | 540 | 680 |
Heavy fuel oil | Kg/h | 278.8 | 348.4 | 418.1 | 553 | 686.4 |
Natural gas | Nm3/h | 296 | 370 | 440 | 592 | 740 |
LPG | Nm3/h | 113 | 130 | 145 | 226 | 260 |
Main steam outlet valve diameter | PN | 16 (20, 25, 40) |
DN | 100 | 100 | 125 | 125 | 150 |
Air vent valve diameter | PN | 16 (20, 25, 40) |
DN | 40 | 40 | 40 | 50 | 50 |
Safety valve diameter | PN | 16 (20, 25, 40) |
DN | 2×50 | 80 / 50 | 80 / 50 | 2×80 | 2×80 |
Water inlet diameter | PN | 16 (20, 25, 40) |
DN | 40 | 40 | 40 | 50 | 50 |
Blow-down valve diameter | PN | 16 (20, 25, 40) |
DN | 2×40 | 2×50 | 2×50 | 2×50 | 2×50 |
Overall dimension | L | mm | 6410 | 6910 | 7330 | 7920 | 8400 |
W | mm | 3250 | 3320 | 3400 | 3560 | 3790 |
H | mm | 4120 | 4230 | 4300 | 4900 | 5530 |
Max. transportation size of boiler (L1xW2xH3) | mm | 5120x2390 x2660 | 5590x2520 x2800 | 5760x2630 x2950 | 6680x2750 x3090 | 7290x2860 x3200 |
Net weight | Ton | 13.8 | 17.1 | 19.5 | 23.6 | 28.8 |
Notes:
1) All of the above values are based on low heat value of light diesel at 10200kcal/kg, low heat value of heavy fuel oil at 9850kcal/kg, low heat value of natural gas(NG) at 8500kcal/Nm³ and low heat value of LPG at 25600kcal/Nm³ as the standard calculations.
2) The above table for the standard configuration of the boiler. According to the special requirements of users, we can provide other evaporation, working pressure or other boilers under special circumstances.
3) The above data is for reference only, the specific calculation data according to drawings or calculation sheets. Company Profile
Manufacturing Procedure
Certifications
Packaging & Shipping
Why Choose Us
FAQS About Delon
DELON has been marketing the industrial steam boilers for nearly 10 years and we have encountered all kinds of problems, here are the most important concerns of our customers before closing the deal.
1) Can your steam boiler meet the heating needs of my production?
If this is your first purchase, all the specifications and the operation requirements should be provided, our engineers will calculate and advice the suitable models for your reference.
2) What are the payment terms?
For new customers, usually we accept the 35% T/T as the prepayment, the balance shall be paid before shipment, and if you have been with us for years or due to the restrictions of foreign exchange policy, we do offer L/C at sight.
3) Do you provide customized service?
We can design the machine according to your requirements (temperature, material, power, control mode, control accuracy, etc.) We will also provide you with expert guidance at the same time, based on our years of experience in this temperature control field.
4) How long does it usually take to manufacture?
Depends on whether you want to do customization your steam boilers or not and also depends on the quantity you want to order.
For regular machines in LCL, the lead time is 20-30 working days.
For customized products and bulk orders in FCL, the lead time is 30-60 working days.
5) What's the warranty for the machine?
Generally, the warranty 24 months counting from the date against shipment, during the warranty period, if there's any parts damaged in quality, you can get the new ones for free.
6) Do you test the machine after the production?
Before shipment, our engineer will arrange the functional tests for each machine.
7) Can I come to China for factory inspection?
Of course, but it is better to wait until the epidemic subsides. Now we support using ZOOM for online factory inspection.
8) Do you offer the spare parts ?
Yes, we will definitely provide the parts along with our boilers at 2 years.
Address:
No. 18, Yangzi Road, Yangshe Town, Suzhou, Jiangsu, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Industrial Equipment & Components, Manufacturing & Processing Machinery, Service
Management System Certification:
ISO 9001
Company Introduction:
Zhangjiagang Delon Thermal Machinery Co., Ltd. is a leading independent heavy machinery supplier in China. We′re a high-tech enterprise integrating energy conservation, environmental protection, clean energy product development, thermal engineering, boilers and pressure vessels. The company has strong technical strength and sophisticated production equipment.
Main Products: Commercial & Domestic Water Heaters, Industrial Boilers, Marine Boilers and other related products including Mold Temperature Controllers, Chillers, etc…
Commercial & Domestic Water Heaters have passed "ISO9001: 2000". The products have "China CCC Compulsory Certification", "EU CE Certification", in line with the commercial electric water heater safety standards stipulated by ASME-HLW and CE.
Industrial Boilers fully implement ISO9001: 2000, ASME and EU CE standards.
Marine Boilers fully implement the quality system standards such as GB/T19001 and CCSR9001, and can design and manufacture products that meet the requirements of CCS, DNV, GL, BV, ABS, RS, RINA and other classification society standards and establish a suitable product.
The purpose of DELON is to carefully design, carefully manufacture and meticulously serve each of your investments; To maximize the return on your investments, as an eternal theme.